Menu Close

Tigerloop Plus Deaerator

Tigerloop Plus De-Aerator

Performance Chart

Max Nozzle Capacity 110 l/h
Max Return Oil Pumped In To The Tigerloop 120 l/h
Max Flow 230 l/h
Max De-Aerating Capacity 8 l/h
Max Operating Temperature 60 Celcius
Max / Min Operating Pressure In The Feed Line +0.5 to -0.6 Bar
thumbnail of Tigerloop_Installation_Instructions
Installation Instructions
SKU: TL61101-P Categories: ,

Description

For external mounting only. This device is not permitted for indoor installation as it vents contaminated air into its surrounding environment, this could create explosion or health hazards in confined spaces and therefore must be fitted on the outside wall of any premises. For situation where the boiler is not mounted to the perimeter wall, such as the Tigerloop BIO or the GOK GS2000 (see separate listings).

The flagship of the Tigerloop range, The Plus features a disposable 15 Micron Particulate Filter, and an outlet pressure gauge

A Tigerloop makes a one-pipe system possible for all types of oil heating installations helping to ensure environmental safety, cost effectiveness and reliability.

Effective de-aeration
In an oil heating system using a Tigerloop, all oil passes through the automatic oil de-aerator, which effectively removes all gas/air bubbles from the system. This eliminates oil pump and nozzle problems associated with gas/air in the oil.

Own two-pipe circulation
An oil pump delivers the same amount of oil irrespective of what is actually needed for combustion. In the case of a normal domestic burner, only 5 % of the delivered oil is actually burned in combustion. The remaining 95% is transported by a two-pipe system back to the oil tank. With a Tigerloop automatic oil de-aerator no oil needs to be transported back to the tank. The oil that is not burned in combustion is lead back to the Tigerloop where it is de-aerated again and again automatically. For this reason only the amount of oil to be burned in combustion is sucked from the oil tank.

Preheated oil
A one-pipe system with Tigerloop increases the oil pump capacity. Moreover, the oil is actually preheated to at least room temperature as friction in the oil pump generates heat. This eliminates problems with cold oil giving cleaner combustion and reduced oil consumption.

Minimum of dirt/sludge
The oil flow in a one-pipe system is minimal due to the fact that only the amount of oil burned needs to be drawn up from the tank. For this reason very little dirt/sludge is transported from the oil tank. This reduces the risk for clogged oil filters and burner nozzles. Filtration is more effective, soot build up is reduced and filter life is extended.

Additional information

Brand

Tigerholm

Condition

New

Max Nozzle Capacity

110lph

Return Flow Rate

120 lph

Max Flow Rate

230 lph

Max Deaerating Capacity

8 lph

Max Operating Temp

60°C

Max Pressure

-0.5 to +0.6 Bar

Filter Included

15 Micron Disposible Element

Isolation Valve

Included

Pressure Gauge

Included

Fittings

All 1/4" BSP